Brief introduction:SBW series three-phase automatic compensation power regulator is designed by our factory to stabilize AC voltage by introducing and absorbing foreign technology in combination with our country's power grid conditions. When the voltage fluctuation caused by voltage fluctuations or load changes in the external power supply network, it can automatically maintain the stability of the output voltage. SBW series voltage regulator series products have the advantages of large capacity, high efficiency,
SBW series three-phase automatic compensation power regulator is designed by our factory to stabilize AC voltage by introducing and absorbing foreign technology in combination with our country's power grid conditions. When the voltage fluctuation caused by voltage fluctuations or load changes in the external power supply network, it can automatically maintain the stability of the output voltage. SBW series voltage regulator series products have the advantages of large capacity, high efficiency, no waveform distortion, stable voltage regulation compared with other types of voltage regulators, SBW high-power regulator is suitable for a wide range of loads, can withstand instantaneous overload, SBW high-power regulator can work continuously for a long time, manual/automatic switching at will, SBW high-power regulator is equipped with overvoltage protection, phase loss, phase sequence protection and automatic protection of mechanical faults, as well as small size, light weight, easy to use and install, reliable operation and other advantages. SBW high-power voltage regulator can be widely used in large-scale mechanical and electrical equipment, metal processing equipment, production lines, construction engineering equipment, elevators, medical equipment, embroidery and textile equipment, air conditioning, radio and television, household appliances, lighting and other places that need voltage regulation in industry, agriculture, transportation, post and telecommunications, military, railway, scientific research and culture, etc. SBW series regulators should be used indoors, and the normal use conditions of SBW regulators are: 1. Ambient temperature: -10°C-45°C 2. Altitude: <1000M 3. Relative humidity: 20%-90% 4. There are no gases, steam, chemical deposits, dust, dirt and other explosive and corrosive media that seriously affect the insulation of the regulator. 5. There is no serious vibration or bump in the installation site of SBW series regulators.
| SBW-S-Series Intelligent Compensated AC Regulator Key Specifications (AVR) | ||
| Infusion | Allowed input voltage range | 3Φ4W+G AC380V±20%, wide range can be specially customized |
| Rated voltage regulation range | 3Φ4W+G AC380V±15%, wide range can be specially customized | |
| Rated frequency | 50HZ/60HZ | |
| lose | Rated output voltage | 3Φ4W+G Line Voltage AC380V (Phase Voltage AC220V) |
| Center voltage | ±5c/o adjustable (line voltage AC360V-400V adjustable) | |
| Voltage regulation accuracy | ±(1-5)c/o selectable, factory setting: line voltage Uab±6V(±1.5c/o) | |
| Response time | ≤0.1s | |
| Stabilization time | ≤1s (10% step change in input voltage relative to rated value) | |
| Waveform distortion | Increment≤0.5% | |
| efficiency | 250KVA and below≥ 97c/o 250KVA and above≥98c/o | |
| Three-phase imbalance | Increment≤0.5% | |
| protection | Overvoltage | If the output line voltage is 10C/O higher than the set value, the alarm will be set and the output will be cut off with a delay of 6 seconds |
| (Overvoltage value and delay time can be set according to user requirements) | ||
| Undervoltage | If the output line voltage is 12c/o below the set value, the alarm will be alarmed and the output will be delayed by 12 seconds | |
| (The undervoltage value and delay time can be set according to user requirements) | ||
| overload | Electronic detection and circuit breaker dual protection (fixed according to model cannot be set): | |
| Long delay beyond the rated load, and cut off the output power supply according to the inverse time limit curve | ||
| Overcurrent | Dual protection of electronic detection and circuit breaker (can be adjusted appropriately according to model and approval) | |
| The short delay is 20 seconds beyond the rated current by 1.2 times, and the output power supply is cut off according to the reverse time limit curve | ||
| short circuit | Circuit breaker protection: Instantaneous cut-off of output | |
| bypass | When the voltage regulator fails or is repaired, it has a power manual pass-through device | |
| Display & Alarm (White LCD Screen on Blue Background) | Input voltage display | Manually switch display (or automatic wheel display): |
| Current 3-phase input line voltage UAB, UBC, UCA (true RMS numerical display) | ||
| Output voltage display | Manually switch display (or automatic wheel display): | |
| Current 3-phase output line voltage Uab, Ubc, Uca (true RMS numeric display) | ||
| Operating current display | Manually switch display (or automatic wheel display): | |
| Current three-phase working current values Ia, Ib, Ic (true RMS numerical display) | ||
| Working status display and alarm records | a. Overvoltage (Up): When the output line voltage Uab, Ubc, and Uca appear Up, it means that the phase is overvolted, and an "Alarm" alarm prompt and alarm sound will appear in the lower right corner at the same time. | |
| b. Down: When the output line voltage Uab, Ubc, and Uca appear Down, it means that the phase is undervoltage, and the "Alarm" alarm prompt and alarm sound will appear in the lower right corner at the same time. | ||
| c. Overload (Up): When Ia, Ib, and Ic appear Up, it means that the phase is overloaded, and an "Alarm" alarm prompt and alarm sound will appear in the lower right corner at the same time. | ||
| d. When the "Alarm" alarm prompt and alarm sound appear in the lower right corner, it means that the voltage regulator currently has an alarm that has not been released; You can view the fault record value and press the "Mute" film key to mute it. | ||
| Control and parameter setting | Microcontroller intelligent detection and control | Microcontroller intelligent detection and control: detects a total of 9 power signals of the regulator input voltage, output voltage, and working current, and after converting it into a digital signal through AD, it sends out corresponding control, display and alarm signals after intelligent judgment by the microcontroller |
| Parameter settings | The voltage regulation accuracy can be set | |
| The output voltage center value can be set | ||
| Overcurrent protection value and delay time can be set (manufacturer approval required) | ||
| The overvoltage protection value and delay time can be set | ||
| The undervoltage protection value and delay time can be set | ||
| Manual voltage regulation/automatic voltage regulation can be switched | ||
| Safety regulations | grounding | Reliable grounding and correct and clear markings |
| Electrical clearance and creepage distance | Greater than 10MM | |
| Insulation resistance | The whole machine is ≥ to the ground 2MΩ (excluding control and instrument display) | |
| Insulation strength | Ground to the ground: AC2000V 50HZ 1 min ≤20mA (excluding control and instrument display) | |
| Input and output wiring | The identification is correct and clear | |
| How it works | It has two working modes: voltage regulation and mains power | |
| Voltage adjustment method | Intelligent (microcomputer control) compensation type | |
| Overload capacity | less than 1.2 times the rated current for 15 minutes; 1.2-2 times the rated current for 20 seconds; | |
| 3 times the rated current for 1 second | ||
| Optional features (additional charge) | 1. Delay output function (add output contactor); | |
| 2. Lightning protection device: It can play a good surge protection when the power grid changes instantaneously and induces lightning strikes. | ||
| 3. EMI filtering device: can effectively filter out harmonic interference in the power grid; | ||
| 4. Phase sequence and phase deficiency protection functions; | ||
| 5. RS485 interface: realize remote control, remote signal, and telemetry functions. | ||
| Model specifications | Rated Capacity (KVA) | Current Rating (A) |
Cabinet dimensions (mm) W x D x H |
weight |
| (kg) | ||||
| SBW-S-20 | 20 | 30 | 600*600*1200 | 165 |
| SBW-S-30 | 30 | 46 | 175 | |
| SBW-S-50 | 50 | 76 | 200 | |
| SBW-S-60 | 60 | 91 | 210 | |
| SBW-S-80 | 80 | 121 | 650*680*1280 | 230 |
| SBW-S-100 | 100 | 152 | 250 | |
| SBW-S-120 | 120 | 182 | 280 | |
| SBW-S-150 | 150 | 228 | 700*850*1500 | 340 |
| SBW-S-180 | 180 | 273 | 380 | |
| SBW-S-200 | 200 | 300 | 400 | |
| SBW-S-225 | 225 | 342 | 465 | |
| SBW-S-250 | 250 | 380 | 485 | |
| SBW-S-320 | 320 | 486 | 800*900*1700 | 580 |
| SBW-S-400 | 400 | 608 | 660 | |
| SBW-S-500 | 500 | 760 | 900*1100*1800 | 830 |
| SBW-S-600 | 600 | 912 | 920 | |
| SBW-S-800 | 800 | 1216 | 1000*1200*2000 | 1100 |
| SBW-S-1000 | 1000 | 1520 |
(1200+1200)*900 *2200 two cabinets |
1700 |
| SBW-S-1200 | 1200 | 1824 | 1900 | |
| SBW-S-1400 | 1400 | 2127 | 2200 | |
| SBW-S-1600 | 1600 | 2431 |
(1200+1100+1400)*900 *2200(three cabinets) |
2700 |
| SBW-S-2000 | 2000 | 3038 | (1400+1100+1100+1400)*900*2200(four cabinets) | 3500 |
| SBW-S-2500 | 2500 | 3800 | (1550+1200+1200+1550)*900*2200 four cabinets | 4200 |
| SBW-S-3200 | 3200 | 4862 | (1500+1500+1500+1500+1500)*1000*2200 five cabinets | 5700 |
| DBW-S-10 | 10 | 45.4 | 600*600*1200 | 150 |
| DBW-S-15 | 15 | 68.2 | 155 | |
| DBW-S-20 | 20 | 91 | 160 | |
| DBW-S-30 | 30 | 136 | 180 | |
| DBW-S-40 | 40 | 182 | 190 | |
| DBW-S-50 | 50 | 228 | 650*680*1280 | 210 |
| DBW-S-60 | 60 | 273 | 650*680*1280 | 220 |
| DBW-S-80 | 80 | 363 | 650*680*1280 | 260 |
| DBW-S-100 | 100 | 454 | 700*850*1500 | 310 |
Website QR code
Hotline:
+86 13311837513
No. 1599 Pingzhuang West Road, Fengxian District, Shanghai
info@cguowen.com